Sustainability and Energy

Hot water pipe insulation and recirculation loops

Hot water that has sat in a long pipe run is cold by the time it reaches the tap, and the energy that heated it has gone. Here is where that loss happens and how to limit it.

Illustration for an article on hot water pipe insulation recirculation

Key takeaways

  • Heat escapes from hot water pipework all the time, and the longer and more exposed the run, the more energy the household pays for before any water reaches the tap.
  • Insulation on the pipes, and on the fittings, is the cheapest way to keep the water hot on its way to the outlet, provided it is kept dry and protected where it is exposed.
  • A recirculation loop saves water while the user waits, but it must be designed and controlled so the water it returns does not sit in the pipes and go stale.
  • Pipe layout matters as much as the insulation, because short runs from the heater to the outlets lose less heat and waste less water than long branches.
  • Installers working in roof spaces and hot ceilings need to plan for heat as carefully as they plan for the pipe, and the water temperature must be managed to limit bacterial growth.

Every hot water system heats more water than the household will use at the tap. Some of that heat leaves the pipework on its way to the outlet, and it leaves whether anyone is using the water or not. The longer and more exposed the run, the larger the loss, and the more time the household spends waiting for hot water to arrive. Both costs are real, and both are set by decisions made during the rough-in, when the pipe is still open and the easy fixes are still available.

This article covers distribution losses in hot water pipework: how heat escapes, how insulation and pipe layout limit it, and what a recirculation loop does and does not solve. It is about the pipes and the fittings between the heater and the outlets. The choice of heater, whether it is a heat pump or another type, is a separate question with its own logic, and our heat pump hot water guide for builders covers that side.

The commercial stake is the callback. A client who finds a bathroom that takes an age to produce hot water, or a bill that is higher than the one they were given, will blame the heater and then the builder. Fixing the heater rarely fixes the problem, because the loss is in the pipe, and the work to correct it inside a finished wall is far more expensive than getting it right during the rough-in.

How heat escapes from a hot water pipe

Hot water in a pipe loses heat to the air around it, and it loses it faster the larger the temperature difference between the water and the surroundings. A pipe run through a cold roof space in winter or a hot ceiling in summer loses heat in different ways, but it loses heat either way. The water also cools when it stands still, so a branch that is used once a day cools completely between uses. Each cold start then sends the cooled water to the drain before the hot arrives, and that water is paid for twice: once to heat it and once to throw it away.

Pipe material affects the rate of loss, but the insulation and the exposure matter more than the material for most residential work. A copper or plastic pipe that is well insulated and short will hold heat better than a long steel run that is bare and laid against a cold external wall. The designer should look at the whole path, from the heater to the furthest outlet, and ask where the water will be exposed and for how long.

The fittings are where many installations lose the most heat. Valves, elbows, tee joints and the bodies of the taps themselves have a surface area that is easy to overlook. Insulate them as well as the straight runs, or the heat will leak from the points that were left out of the plan. A pipe that is well wrapped and then passes through a bare valve body is only half done.

Heat lost in the pipework is paid for twice over, once in fuel and again in the water that runs away while the tap warms up.

Pipe layout: the decision that is hardest to change

Layout decides how far the water has to travel before it reaches each outlet, and that is the single biggest factor in the heat and water lost on the way. A layout that runs a single long main to the far end of the house and then branches back to the bathrooms holds a large volume of cooled water in the pipe at all times. A layout that brings the main as close to the outlets as possible keeps the volume small and the wait short.

Where the house plan allows it, group the wet areas so that the kitchen, the laundry and the bathrooms share a short run from the heater. Avoid running a long branch to a single outlet that is used rarely, such as a guest bathroom at the far end of the house, unless it is insulated and the household accepts the wait. The plumber will often prefer a long run because it is simpler to route, and the builder is the one who should ask for the short run and explain the saving to the client.

Water efficiency is a whole-house question, and fittings are part of it. Taps and showers rated under the Water Efficiency Labelling and Standards (WELS) scheme use less water for the same service, which means less hot water to heat and less cold water wasted while the tap warms up. Our article on greywater reuse for residential builders covers a different route to water savings, and the two can be planned together.

The first run from the heater does the most work

The pipe closest to the heater carries the hottest water in the system, and it is the run that is used most often. Every outlet in the house draws through it, so any heat lost there is lost on every use. That is why the first section of pipe is the most important one to insulate, and why it should be insulated before anything further along the line. Installers sometimes leave the early run bare because it is short and easy to reach, and that is the wrong place to economise.

The connections at the heater deserve the same care. The isolating valves, the fittings where the pipe meets the unit and any arrangement for relieving pressure are places where heat and water can escape, and they are often the first things a service visit needs to reach. Leave them accessible, insulate them to the same standard as the pipe they serve, and keep the insulation clear of any part of the unit that the manufacturer requires to be kept open.

Insulation: what it does and where it goes

Insulation on hot water pipes works by slowing the rate at which heat passes through the pipe wall into the surroundings. It is most effective on the runs that are long, exposed or uninsulated by the building itself, which usually means the pipes running through roof spaces, under floors and along external walls. The insulation should be the type and thickness the manufacturer specifies for the pipe and the location, and that specification is the figure to check on the job rather than a rule of thumb.

Protect the insulation where it is exposed. Pipes that run outside, under a deck or through a sunlit roof space need insulation that resists ultraviolet light and a jacket that keeps moisture out. Wet insulation loses much of its value and can hold moisture against the pipe, which is the start of corrosion and the wrong place to find it. Seal the joins and make sure the insulation is continuous over every fitting it passes.

Before the insulation goes on

  • Every exposed hot water pipe and fitting is accessible and the joints have been tested and dried.
  • The insulation is the type and thickness the manufacturer specifies for the pipe and the location.
  • Insulation exposed to sunlight or weather has UV-resistant protection and is sealed against moisture.
  • The loop, if fitted, has its controls in place and the return line is sized and routed as designed.
  • The water temperature the system will hold has been set to the level required to control bacteria.
  • The work is planned around heat in the roof space, with water and shade available for the crew.

Recirculation loops: what they fix and what they create

A recirculation loop keeps hot water moving around a pipe circuit so that a tap anywhere on the loop delivers hot water quickly. The wait at the tap falls, and so does the water wasted while waiting. Where a household has a long run and a frequently used outlet, a loop can save a great deal of water. The price is that the loop itself loses heat, and it does so continuously if it is not controlled.

A long branch line and a managed recirculation loop

LayoutWhat the household gets and what it costs
Long branch line, uninsulatedThe water cools in the pipe between uses, the wait at the tap is long, and every cold start runs water to waste.
Short run, insulatedLess heat is lost on the way to the outlet, the wait is shorter and the water used while waiting is much less.
Recirculation loop, controlledThe wait is short at any outlet, but the loop adds its own heat loss and must be timed or sensor-controlled so it is not running all day.
Recirculation loop, uncontrolledThe loop runs constantly, the heater works harder and the water in the return line can sit below the temperature needed to control bacteria.

An uncontrolled loop that runs all day is the version that causes the most trouble. It keeps the heater working in the middle of the night, it adds to the bill, and the water in the return line can sit at a temperature that does not control bacteria. A loop should be controlled by a timer, a temperature sensor or a demand switch, so that it runs when it is needed and stops when it is not. The return line should also be sized and routed as designed, because a line that is too long or badly connected stagnates and becomes the place where problems grow.

Bacteria are the reason the loop must be designed as a system rather than as a convenience. Water that stands in pipes at lower temperatures can support the growth of organisms that are dangerous to people, and the risk is greatest in the return lines and the parts of the loop that are used least. The storage temperature and the loop design need to be set to the standard that controls the risk, and that standard should be confirmed for the job rather than guessed.

The mistake that costs the most. Running a long, bare hot water branch to a far bathroom, then sizing or upgrading the heater to fix the complaints about waiting. The heater works harder, the bill goes up, the water runs to waste at every cold start, and the real problem sits in the pipe where nobody looks. The fix is the layout and the insulation, and both are far cheaper during the rough-in.

Designing for how the household actually uses water

Households do not use hot water the way a design sheet assumes. People run the tap while they wait, fill a bucket to rinse something, leave the shower running while they find a towel and draw a bath the moment the water is warm enough to be comfortable. Each of those habits is a loss, and the design can reduce the cost of them without asking anyone to change their routine. A branch that is short and insulated means the wait is shorter, and the habit of running the water to fill the time stops costing so much. Sizing the heater to the household is a separate job, set out in our article on sizing hot water for household demand.

Think about the outlets that are used together. A kitchen and a laundry drawing hot water at the same time will compete for the same supply if they share a small pipe, and the pressure and the temperature at each will suffer. Where the plan allows, give the heavy users their own branch from the main, and check the layout against the way the house will be lived in rather than the way it is drawn. A family that runs a dishwasher and a shower in the same part of the morning will notice the difference at once.

Explain the trade-off to the client before handover, in plain words. A client who understands that a loop costs something to run, and that a long branch wastes water while it waits, can make an informed choice about how the system is used. A client who was never told will assume the system is faulty when the bill or the wait does not match what they expected.

Commissioning the system and handing it over

Commission the hot water system before the house is handed over, and record what was checked. The temperature at the furthest outlets should be measured once the system has been running long enough to reach its normal operating condition, and it should be checked against the temperature the design requires and the temperature needed to control bacteria. Where a mixing valve is fitted to limit the temperature at the outlets for safety, confirm its setting and record it, because a valve that a later tradie has adjusted without a record is a hazard nobody can trace.

Balance the system where the design calls for it. A loop without a balancing valve may send most of the flow to the outlets nearest the pump, leaving the far outlets slow and cold. Setting the balance valves to the design and checking the result at each outlet takes a short time on the day and saves a callback that is much longer. Record the settings in the handover pack with the layout drawing, so the next person to service the system does not have to rediscover them.

Give the owner a short written note: how the loop is controlled, when it runs, what the timer or sensor is set to, and who to call if the water stops being hot. That note is what keeps a sound installation performing as designed over the years. A system nobody understands gets adjusted until it stops working, and then it is blamed on the builder.

Working safely on the install

The installer working on hot water pipework in a roof space in summer is working in a hot environment and often in a confined one. Heat, dehydration and burns from hot pipes are all real hazards, and the crew should plan for them as they would for any other task on the job. Safe Work Australia publishes guidance on working in heat, and the principles apply directly: schedule the hottest work for the cooler parts of the day, provide water and shade, and rest people before they are exhausted.

Hot pipes can burn on contact, and a hot water line that has been running for some time will be hotter than the crew expects. Let the pipes cool or use the right gloves before handling them, and keep the crew away from the outlets while the system is being tested. Insulation that is being fitted on a hot day can also become a hazard if it is handled carelessly, and the crew should wear suitable protection.

Plan the testing as part of the install. Test the pipework for leaks before the insulation goes on, and retest after it is fitted, because the insulation can hide a joint that has started to weep. A leak found on the day costs a little time. A leak found after the plasterboard is up costs a wall. Installers who want structured CPD on this kind of work can start with the PointCPD course catalogue.

A worked example: a long run to a far bathroom

A builder in western Sydney was finishing a new home with a central hot water system. The plumber had run the main from the heater along the length of the house, with the bathroom at the far end fed by a branch that had not been insulated because it ran through an internal wall. When the family moved in, the complaint was the wait at the far bathroom shower, which was long enough that the family had started running the water to fill the time.

The builder’s first step was to measure the wait and the water used, and to confirm the layout against the plan. The main was then re-routed closer to the wet area, which was possible because the wall that carried the pipe could be opened during the defects visit. The branch was insulated throughout, including the fittings, and a timed recirculation loop was added with a control that stopped it outside the hours the family used the shower.

The result was a short wait at the far bathroom and a lower cost of hot water for the household. The builder did not need to upgrade the heater, which would have been the expensive answer. The lesson the builder took was simple: check the layout and the insulation before the heater, because the heater is the last thing that should be asked to solve a pipe problem.

Questions builders ask

Is it worth insulating hot water pipes in a new home?

Yes, in most new homes. Insulation on the runs that pass through roof spaces, under floors and along external walls keeps more of the heat at the tap and reduces the water wasted while the tap warms up. Use the type and thickness the manufacturer specifies, and protect the insulation wherever it is exposed to sunlight or moisture.

Do hot water recirculation loops save water?

A well-designed loop saves water by bringing hot water to the tap quickly, so less cold water runs to waste. It also uses energy to keep the loop warm, so it should be timed or controlled so that it runs only when needed. A loop that runs all day can cost more than it saves.

Can a recirculation loop create a health risk?

It can, if the water in the loop sits at a temperature that does not control bacteria, and the return line is the most likely place for the problem. Design the loop as a system, set the storage and loop temperatures to the standard that controls the risk, and confirm the setting for the job. Do not guess at it.

Should the heater be upsized to fix slow hot water at a far outlet?

Usually not. Slow hot water at a far outlet is most often caused by a long, uninsulated branch that holds cooled water, and a bigger heater does not fix that. Check the layout and the insulation first, because the cheapest fix is usually in the pipe, not the heater.

Does heat loss from hot water pipes matter for water efficiency?

It does. Cold water that is drawn off while the hot water arrives is wasted, and a long run wastes more of it every time a tap is opened. Shorter runs, insulation and efficient fittings all reduce the amount of water and energy used before the hot water reaches the user.

What should installers watch for when working on hot water pipework in summer?

Heat exhaustion in roof spaces is the main hazard, followed by burns from hot pipes. Plan the hottest work for the cooler parts of the day, provide water and shade, and rest people before they are exhausted. Test the pipework for leaks before the insulation goes on, because a leak found after the wall is closed is far more expensive to fix.