Regulation and Compliance

Structural engineer certificates: what builders should get in writing

An engineer’s certificate is only useful if it describes the work that is actually in the ground and on the frame, and the builder is the one who has to make that match.

Illustration for an article on structural engineer certificate builder nsw

Key takeaways

  • An engineer’s certificate covers the stage and the work it names, so the builder must match each certificate to the as-built element it describes before it is filed.
  • A change on site that departs from the approved drawings needs the engineer’s review before the work is covered, because a certificate written for the original design does not cover the new one.
  • Get the certificate in writing, dated, signed and referenced to the drawings, and never accept a verbal assurance in place of the document the certifier will read.
  • Hold the engineer’s certificates, the inspection records and the as-built drawings together in the job file, because the certifier and the owner will need them long after the crew has left.
  • Check the set of certificates against the list of structural elements before the occupation stage, so any gap is found while the work can still be inspected or documented.

Every residential frame carries a set of structural decisions that the builder did not design but has to build. The footings, the beams, the connections, the bracing and the tie-down all rest on an engineer’s calculations and drawings. When the work is done and the certifier asks for proof that it matches the design, the answer is a stack of certificates and inspection records that the builder is responsible for assembling.

That stack is the builder’s evidence trail. It shows that the engineer reviewed the work, that the work was inspected at the points the design required, and that the as-built structure is the structure the design approved. A builder who understands the trail can produce it quickly and defend it. A builder who treats the certificates as paperwork to be filled in at the end usually finds gaps that cannot be closed without opening up finished work.

This article is about engineers’ certificates and inspections as that evidence trail. It covers matching each certificate to the work it describes, handling a change on site, and holding the documents for the certifier and the owner. It does not cover the inspection stages in general, which the building inspections article describes, or the conditions attached to a construction certificate, which have their own article.

The focus here is what the builder should have in writing, and how to make sure it describes the work that was really built.

A certificate proves a structure only when the paper describes the same frame that is standing on the site.

What an engineer’s certificate actually covers

An engineer’s certificate is a statement by a qualified engineer about a particular part of the work. It may say that the footings were inspected before the concrete was poured, that the connections were installed in line with the design, or that a retaining wall or a suspended slab was built to the drawings. Each certificate is limited to what it names. It does not certify the whole house, and it does not certify work the engineer did not see.

That limit is the first thing a builder has to understand. A certificate for the footings says nothing about the frame that sits on them, and a certificate for the frame says nothing about a bracing wall added later. When the certifier reviews the file, each certificate is read against the element it names. If the element on site is not the element the certificate describes, the certificate does not help, however well it is written.

The certificate should refer to the drawings and the revision the engineer reviewed. A certificate that says the work follows the design, with no drawing reference, leaves the certifier guessing which design was meant. Ask the engineer to reference the drawing number and revision in every certificate, and check that the revision matches the approved set on the job file.

Matching each certificate to the as-built work

The most common gap in a structural file is a certificate that describes an element that was built differently. A footing is poured at a different depth from the one drawn, a beam is replaced with a larger member, or a connection is changed because the specified fixing was not available. The certificate still refers to the original design, and the builder has a certificate that does not match the work.

The fix is to match each certificate to the as-built element at the time it is issued. Walk the frame with the certificate in hand, and check that the member, the connection or the footing named in the certificate is the one in place. Note any difference on the spot, and get the engineer to review it before the element is covered. A builder who does this at the time avoids the far harder job of proving the match after the wall has been lined.

Keep a simple register that lists each structural element, the certificate that covers it, the drawing revision and the date of the inspection. The register is not a legal document, but it shows the certifier that the builder has tracked the work element by element, and it makes it obvious where a certificate is missing.

Be realistic about what an engineer can see. An engineer who inspects a footing before the pour can confirm the excavation, the reinforcement and the bearing as they stood at that moment. The engineer cannot confirm the concrete that arrives later unless the testing and the pour records say so. The certificate should say what was seen, and the builder should not ask for a certificate that is wider than the inspection that supports it.

Matching each certificate to the work before it is covered

  • Confirm the element named in the certificate is the element in place, with the same member, size and connection.
  • Confirm the certificate refers to the drawing and revision the crew built from.
  • Note any difference from the design on the spot and send it to the engineer before the work is covered.
  • Confirm any substituted product has evidence the engineer has accepted for that connection.
  • Confirm the inspection is booked and held as a stop point before the element is covered.
  • Record the inspection date, the person, the element and the outcome in the register.

Changes on site and the review that must come first

Changes happen on every job. A beam is not available in the size drawn, a wall is moved to suit a window, or the ground turns out to be different from the investigation. Some changes are minor and some are not, and the builder has to tell them apart before the work goes ahead. The test is whether the change alters a structural element, a load path or a connection shown in the approved design.

If it does, the change needs the engineer’s review before the work proceeds, and the review needs to be in writing. A verbal approval from the engineer on site is not enough, because the certifier will need to see the amended design and the certificate covering the changed work. Building over an unapproved change means the covered work cannot be inspected or documented, and the cost of opening it up falls on the builder.

Keep a record of the decision, not just the outcome. A short note that says what changed, why, who approved it and which drawing revision now applies is worth more than a folder of messages. The note should go into the register alongside the certificate it affects, so that the file tells one consistent story.

Some changes need more than a review. A change to the design may need a modified drawing or a new approval from the certifier, depending on the nature of the change and the stage of the job. The construction certificate conditions article is a useful companion on this point. The builder should ask the certifier early, rather than assume that a change the engineer accepts is also a change the certifier accepts.

The beam swapped on a Friday. The mistake that costs the most is replacing a structural member with a different size or grade on site because the drawn one is not available, then covering the work before the engineer has reviewed the change. The certificate on file describes a beam that is no longer in the wall, and the only fix is to open the wall again.

Products, substitutions and alternative solutions

Substitutions often sit inside a structural connection. A bracket, a fixing or an anchor is replaced by an equivalent product, and the builder assumes the equivalence is obvious. The Australian Building Codes Board publishes the Evidence of suitability handbook, which sets out the kinds of evidence used to show that a product or method meets the performance requirements. The principle the builder needs is simple: a product is accepted on evidence that it performs as the design requires, not on a similar name.

Where a product is substituted, get the evidence for the substitute and have the engineer confirm it is acceptable for the connection. The same applies to a system the designer has specified under a certification scheme. CodeMark is a certification scheme for building products and designs, and a builder who substitutes a product covered by that scheme should check that the substitute carries an equivalent certification.

Keep the substitution evidence with the engineer’s certificate that covers the connection. A certifier who finds a product on site that differs from the drawing will ask for the evidence, and a file that shows the request, the response and the engineer’s acceptance is a short conversation rather than a long one.

Ask the engineer to say what was not inspected. A certificate that is silent about the parts the engineer did not see is more useful than one that quietly assumes they were fine, because the certifier can then ask for the missing evidence while the work is still reachable. A clear statement of the limits protects the engineer, the builder and the owner in the same way.

Inspections that the engineer must see

Some structural work needs an inspection while it is still visible, before it is covered. Footings, reinforcement, connections in the frame and bracing are the usual examples. The inspection has to happen at the stage the design requires, and the engineer has to see the work the certificate describes. A certificate issued from the drawings, with no inspection, is weaker evidence than one issued after the engineer has looked at the element.

Book the inspection before the work is covered, and plan it against the stages set out for the job. A slab poured before the reinforcement is inspected, or a wall lined before the bracing is checked, cannot be assessed properly after the event, and the engineer may have to refuse the certificate or ask for the work to be opened up. The builder who books the inspection as a hold point in the program avoids that problem.

Keep a record of each inspection: the date, the person, the element inspected and the outcome. Attach the photograph if the engineer provides one. The inspection record is the proof that the engineer saw the work, and it is the first document the builder will be asked for if the certificate is questioned.

A worked example: the frame with the missing certificate

Consider a builder in the Blue Mountains who is finishing a double-storey residence on a sloping block. The engineer has issued certificates for the footings and the main frame, and the builder has them on file. During the lining stage the certifier asks for the certificate covering a set of steel connections at the upper floor, which the builder had not requested because the connections were not on the engineer’s list.

The builder checks the drawings and finds that the connections were shown on a later revision of the frame design, which had been issued while he was on another job. The crew installed the connections from the later drawings, but the engineer’s certificate and the register both refer to the earlier revision. The work is correct in substance, but the file does not show it.

The builder calls the engineer, sends the later drawing and the photographs of the connections, and asks for a certificate that refers to the correct revision and covers each connection by name. The engineer inspects the connections, which are still accessible because the lining has not gone on. The certificate is issued the following week, and the certifier accepts the file.

The lesson is that the certificates have to follow the drawings, and the builder has to know which drawing revision the crew is building from. The engineer was never at fault, and the work was never wrong. The gap was in the link between the drawings and the paperwork, and the fix was a phone call and a short inspection while the work was still open.

Holding the documents for the certifier and the owner

The engineer’s certificates, the inspection records and the as-built drawings belong in one place, and that place should outlive the job. The certifier will want to see them at the occupation stage, and the owner may need them years later when they renovate, sell or insure the house. A file that cannot be found in five years is almost as bad as a file that was never kept.

Keep a digital copy as well as the paper original, and back it up somewhere other than the site office. A file held only on a laptop that is lost in a theft or a fire is no file at all. The owner’s copy should be a complete copy rather than a summary, and the builder should keep a record of what was sent and when. If the owner later needs the certificates for a sale or an insurance claim, the builder who can produce them within a day keeps the client’s confidence.

Store the documents in a form that is easy to search and hard to lose, and give the owner a copy at handover. Note the drawing revisions and the certificates in the handover pack, so a future builder or engineer knows what the structure is and how it was checked. The NSW Department of Planning guidance on getting an occupation certificate is a useful place to check what the occupation stage expects of the file.

Check the set of certificates against the list of structural elements before the occupation stage. Any gap found at that point can often be closed while the work is still accessible or can be documented from the engineer’s records. A gap found after the owner has moved in is much harder to close.

Building the evidence trail from footing to handover

  1. Design issuedThe engineer’s drawings and the approved revision are placed in the job file.
  2. Inspection before coverThe engineer sees the footing or the frame element while it is still visible.
  3. Certificate issuedThe certificate names the element, refers to the drawing revision and is dated and signed.
  4. Change reviewedAny site change is sent to the engineer in writing before the work is covered.
  5. File checked and handed overThe certificates, records and as-built drawings are checked against the element list and given to the owner.

Certificates are part of the professional competence a builder brings to a job, and the professional development that supports it is set out in the PointCPD guide to NSW builder CPD. The course catalogue lists modules on compliance and documentation that cover the same evidence trail from the builder’s side.

A structural certificate is only as good as the match between the paper and the frame. Read each certificate against the element it names, get changes reviewed before they are covered, and keep the whole trail together where the certifier and the owner can find it.

Questions builders ask

What should an engineer’s certificate for a residential frame include?

It should name the element or stage it covers, refer to the drawing and revision reviewed, state what was inspected, and be dated and signed by the engineer. A certificate without a drawing reference or a named element leaves the certifier guessing what it covers.

Does one engineer’s certificate cover the whole house?

No. A certificate covers the work it names, and the work the engineer actually saw or reviewed. Each structural element may need its own certificate, and the builder should check the list of elements against the certificates before the occupation stage.

What do I do when a beam on site is not the size drawn?

Stop before covering the work and send the change to the engineer in writing, with a photograph and the reason for the change. Do not cover the element until the engineer has reviewed it and the certificate or amended design reflects what is in place.

Can I use an equivalent connection product without the engineer?

Not safely. An equivalent product needs evidence that it performs as the design requires for that connection, and the engineer should confirm it is acceptable. Keep the evidence and the engineer’s response with the certificate that covers the connection.

Who holds the structural documents after handover?

The builder should keep a complete copy of the certificates, inspection records and as-built drawings on the job file and give the owner a copy at handover. The documents are needed by the certifier at the occupation stage and by the owner for later renovation, sale or insurance.

Is an inspection needed if the engineer has already issued a certificate?

It depends on the element and the stage. Where the design requires the engineer to see the work before it is covered, the certificate needs that inspection to stand behind it. Book the inspection as a hold point before the element is covered, so the certificate can be issued from what the engineer actually saw.